Product category • ATEX

ATEX Areas

Third-party certified ATEX vacuums for Dust Zone 22 and 21 and Gas Zone 2 and 1 in pharma production. All models comply with EN 17348:2022 and directive 2014/34/EU. ESD-safe and approved for continuous duty.

ATEX Areas — 35 models

C-7 EX (4W)

Tiger-Vac

C-7 EX (4W)

Likely the smallest third-party certified ATEX vacuum for Zone 20 and 22. Just 77.5 cm tall and 23 kg. LCIE 15 ATEX 3061 + IECEx LCIE 15.0048. 194 m³/h. 72 dB(A). 19 L.

C-10 EX (4W) EU

Tiger-Vac

C-10 EX (4W) EU

ATEX II 1/3D. Zone 22 external (cat. 3D), Zone 20 internal (Da). Third-party cert. LCIE 15 ATEX 3061 + IECEx LCIE 15.0048. HEPA/ULPA 20,253 cm². 194 m³/h. 72 dB(A). 19 L. 24 kg.

EXP1-5 (4W) RE HEPA

Tiger-Vac

EXP1-5 (4W) RE HEPA

The industry’s smallest ATEX-certified canister vacuum. ATEX II 2GD. HEPA H14 included. Zone 1 gas, Zone 21 dust. Lightweight and compact — only 27 kg. TEFC motor 1 kW, 230 V. 224 m³/h. LCIE 03 ATEX 6297. EN 17348 DT/LC. 12.9 L collection.

SS-ARU-15 EX (TC) MRAC

Tiger-Vac

SS-ARU-15 EX (TC) MRAC

Pneumatic ATEX-certified wet vacuum (II 2GD) for safe recovery of acids and corrosive liquids in Zone 1 and Zone 21. HEPA filter included. Activated carbon filter optional.

CD-595 EX HEPA VOC

Tiger-Vac

CD-595 EX HEPA VOC

ATEX-certified stainless-steel fume and VOC extractor (II 1/2 GD) with three-stage filtration: spark trap, HEPA H14 and 12 activated-carbon cartridges. For safe capture of fumes, vapours and organic gases in Zone 1 and Zone 21.

MTL301 1/2D

Delfin

MTL301 1/2D

ATEX Zone 21 compact dry vacuum. AISI 304 stainless steel. HEPA H14 included. Disposable filter bag. 1.1 kW. 215 m³/h. 40 L. EN 17348.

MTL301 1/3D

Delfin

MTL301 1/3D

Compact ATEX Zone 22 certified industrial vacuum for dry dust. 1.1 kW, 2,500 mmH₂O vacuum. H14 HEPA. 40 L AISI 304. EN 17348:2022. IECEx.

EXP1-10 (4W) RE HEPA (MRAC)

Tiger-Vac

EXP1-10 (4W) RE HEPA (MRAC)

ATEX II 2GD certified wet & dry vacuum with activated carbon filter (MRAC) and HEPA H14 included. Adsorbs toxic fumes and gases. Zone 1 gas, Zone 21 dust. TEFC motor 1 kW, 230 V. 224 m³/h. LCIE 03 ATEX 6297. EN 17348 DT/LC. 37 kg.

EXP1-10/15 (4W) RE

Tiger-Vac

EXP1-10/15 (4W) RE

ATEX II 2GD certified pharma and cleanroom vacuum. ISO Class 4. Wet and dry collection. Two sizes: EXP1-10 (22.7 L) and EXP1-15 (38 L). HEPA H14 included. Zone 1 gas, Zone 21 dust. TEFC motor 1 kW, 230 V. 224 m³/h. LCIE 03 ATEX 6297. EN 17348 DT/LC.

MTL201 1/2D

Delfin

MTL201 1/2D

ATEX Zone 21 compact dry vacuum with Dustop filter cleaning. AISI 304 stainless steel. HEPA H14 included. Tangential cyclone. 1.1 kW. 215 m³/h. 20 L. EN 17348.

MTL201 1/2D LP

Delfin

MTL201 1/2D LP

ATEX Zone 21 dry vacuum with Longopac dust-free emptying. HEPA H14 included. 1.1 kW. 215 m³/h. 20 L. EN 17348.

EXP1-20L (DT) RE HEPA (MFS)

Tiger-Vac

EXP1-20L (DT) RE HEPA (MFS)

Explosion proof industrial vacuum (ATEX II 2GD) with HEPA H14, detachable 25 L tank and full antistatic protection below 10 ohms. Cleanroom compatible (ISO Class 4). Zone 1 gas, Zone 21 dust. 1 kW. 224 m³/h. LCIE 03 ATEX 6297. EN 17348 DT.

EXP1-35L (DT) RE HEPA (MFS)

Tiger-Vac

EXP1-35L (DT) RE HEPA (MFS)

Explosion proof industrial vacuum (ATEX II 2GD) with HEPA H14 and large 35 L detachable tank. Full antistatic protection below 10 ohms. Cleanroom compatible (ISO Class 4). Zone 1 gas, Zone 21 dust. 1 kW. 224 m³/h. LCIE 03 ATEX 6297. EN 17348 DT.

EXP1-40L (4W) RE HEPA (FR-P)

Tiger-Vac

EXP1-40L (4W) RE HEPA (FR-P)

ATEX II 2GD certified vacuum for unburnt gunpowder dust, lead and pyrotechnics. Large 38 L tank. HEPA H14 included. Zone 1 gas, Zone 21 dust. TEFC motor 1 kW, 230 V. 224 m³/h. LCIE 03 ATEX 6297. EN 17348 DT/LC. Conductive polyliner bag included.

EXP1-55L DT EXTENDED (MFS) RE HEPA

Tiger-Vac

EXP1-55L DT EXTENDED (MFS) RE HEPA

Explosion proof industrial vacuum (ATEX II 2GD) with HEPA H14 included and large 55 L detachable tank. Teflon-laminated cloth filter. Zone 1 gas, Zone 21 dust. 1 kW. 224 m³/h. ISO Class 4. LCIE 03 ATEX 6297. EN 17348 DT.

EXP1-10 (25L) DT RE HEPA MFS (SS-FOD CART)

Tiger-Vac

EXP1-10 (25L) DT RE HEPA MFS (SS-FOD CART)

Explosion proof industrial vacuum (ATEX II 2GD) with HEPA H14, detachable 25 L tank and stainless steel FOD cart. Cleanroom compatible (ISO Class 4). Zone 1 gas, Zone 21 dust. 1 kW. 224 m³/h. LCIE 03 ATEX 6297. EN 17348 DT.

DM2 EL 1/2D

Delfin

DM2 EL 1/2D

ATEX Zone 21 robust mobile vacuum. 100 L AISI 304 stainless steel. HEPA H14 included. 2.2 kW. 430 m³/h. EN 17348.

DM2 EL 1/2D LP

Delfin

DM2 EL 1/2D LP

ATEX Zone 21 vacuum with Longopac dust-free emptying. HEPA H14 included. 2.2 kW. 430 m³/h. EN 17348.

DM2 EL 1/3D

Delfin

DM2 EL 1/3D

Powerful ATEX Zone 22 certified industrial vacuum for dry dust and solid particles. 2.2 kW, 2,500 mmH₂O vacuum. H14 HEPA. 60 L AISI 304. EN 17348:2022. IECEx.

CD/EUR-25L EX DT (MFS)

Tiger-Vac

CD/EUR-25L EX DT (MFS)

Compact explosion proof vacuum (ATEX II 1/2 GD) with True Cyclone Separator, manual filter shaking (MFS) and detachable 25 L tank. HEPA and ULPA as options. Zone 1 gas, Zone 21 dust. 2.2 kW / 1.5 kW. 212 m³/h. LCIE 03 ATEX 6295 X.

CD/EUR-36L EX DT (MFS) ULPA WITH SS CART

Tiger-Vac

CD/EUR-36L EX DT (MFS) ULPA WITH SS CART

Explosion proof pharmaceutical vacuum (ATEX II 1/2 GD) with ULPA U15 included, manual filter shaking (MFS) and detachable 36 L tank on stainless steel cart with ESD wheels. Zone 1 gas, Zone 21 dust. 2.2 kW / 1.5 kW. 212 m³/h. 72 dB(A). LCIE 03 ATEX 6295 X.

CD/EUR-36L EX DT (MRP) ULPA WITH SS CART

Tiger-Vac

CD/EUR-36L EX DT (MRP) ULPA WITH SS CART

Explosion proof pharmaceutical vacuum (ATEX II 1/2 GD) with ULPA U15 included and manual reverse pulse cleaning (MRP). Detachable 36 L tank on stainless steel cart with ESD wheels. Zone 1 gas, Zone 21 dust. Up to 2.2 kW. 212 m³/h. LCIE 03 ATEX 6295 X.

MTL201 1/3D

Delfin

MTL201 1/3D

Compact ATEX Zone 22 certified industrial vacuum for dry dust. 1.1 kW, 2,500 mmH₂O vacuum. H14 HEPA. 20 L AISI 304. EN 17348:2022. IECEx.

DG30 EXP EX1/2D

Delfin

DG30 EXP EX1/2D

ATEX Zone 21 three-phase side channel blower. 100 L stainless steel. HEPA H14 included. 4 kW. 420 m³/h. IP65. EN 17348.

DG70 EXP EX1/2D

Delfin

DG70 EXP EX1/2D

ATEX Zone 21 high-power three-phase side channel blower. 100 L stainless steel. HEPA H14 included with 52,000 cm² filter area. 5.5 kW. 560 m³/h. IP65. EN 17348.

CD-600 EX HEPA Stainless Steel

Tiger-Vac

CD-600 EX HEPA Stainless Steel

ATEX II 1/2 GD certified stationary stainless steel vacuum with HEPA H14 included. Zone 1 gas and Zone 21 dust. TEFC motor 2.2 kW (400 V) or 1.5 kW (230 V). 1,000 m³/h. LCIE 03 ATEX 6295 X. IECEx. EN 17348 DT. IP65. 160 kg.

CD-1200 EX Stainless Steel

Tiger-Vac

CD-1200 EX Stainless Steel

ATEX II 1/2 GD certified stationary stainless steel vacuum for Zone 1 gas and Zone 21 dust. TEFC 4 kW three-phase motor. 2,000 m³/h. LCIE 03 ATEX 6295 X. IECEx. EN 17348 DT. IP65. 215 kg.

DBF 05/10 Z22

Delfin

DBF 05/10 Z22

ATEX Zone 22 certified version of the DBF 05/10. Bag filter with H14 absolute filter as standard. Compact horizontal construction. EN 17348. IP65.

DBFV 05/10 Z22

Delfin

DBFV 05/10 Z22

ATEX Zone 22 certified version of the DBFV 05/10. Vertical construction with bag filter and H14 absolute filter as standard. EN 17348. IP65.

DBFV 20/30 Z22

Delfin

DBFV 20/30 Z22

ATEX Zone 22 certified version of the DBFV 20/30. Vertical construction with star filter, manual cleaning and H14 absolute filter as standard. EN 17348. IP65.

PHARMA 20.18 ATEX

Delfin

PHARMA 20.18 ATEX

ATEX Zone 22 certified pharmaceutical dust collector. AISI 304 stainless steel. H14 absolute filter as standard. Safe bag system. EN 17348. 270 m³/h. 22 L.

PHARMA 40.30/40.40 Z22

Delfin

PHARMA 40.30/40.40 Z22

ATEX Zone 22 certified pharmaceutical dust collector. AISI 304. H14 absolute filter as standard. Two motor sizes: 3 kW and 4 kW. 42 L. EN 17348.

CD-230V EX (CFB) PHARMA

Tiger-Vac

CD-230V EX (CFB) PHARMA

Explosion proof pharmaceutical vacuum (ATEX II 1/2GD) with ULPA U15 and conductive collection filter bag. Continuous duty. 50 L stainless steel Type 304 tank. Zone 1 gas, Zone 21 dust. 1.5 kW. 212 m³/h. 68 dB(A). LCIE 03 ATEX 6295 X.

CD-230V EX MRPFT HEPA

Tiger-Vac

CD-230V EX MRPFT HEPA

Explosion proof industrial vacuum (ATEX II 1/2GD) with built-in filter tube purge system and HEPA H14. Continuous duty. 50 L stainless steel Type 304 tank. Zone 1 gas, Zone 21 dust. 1.5 kW. 212 m³/h. 2,540 mmH₂O. LCIE 03 ATEX 6295 X.

CWR-10 EX (CV)

Tiger-Vac

CWR-10 EX (CV)

ATEX II 3D certified containment vacuum with sealed single-use canister in AISI 430 stainless steel — 12, 20 or 40 L. 5-stage filtration with dual ULPA U15. EMI/RFI shielded and ESD safe. ISO 4 compatible. OEB 4–5. 75 dB(A).

Zones, categories and what the certificate actually covers

ATEX is the collective term for two EU directives: 2014/34/EU governing the equipment, and 1999/92/EC governing the workplace. Certified equipment is designed and tested not to act as a source of ignition. Every machine in this category is third party certified and complies with EN 17348:2022.

The internal zone is the one that gets overlooked

EN 17348 introduced the concept of the internal ATEX zone. Inside the collection system itself the dust concentration is far higher than in the surrounding room, so the interior of the machine is classified in the same way the workplace is. A machine marked Zone 22 externally may be Zone 20 internally. It is that combination which determines whether the machine may in fact be used where you intend to use it.

Accessories are part of the certification

EN 17348 explicitly covers hoses, couplings, nozzles and filters. They form an integral part of the certified system rather than loose parts. A certified machine fitted with an uncertified hose is not a certified system.

When ATEX and OEB apply to the same compound

Many highly potent active ingredients are also combustible. The two sets of requirements then arise together, and the machine must be both certified for the zone and closed enough for the OEB level of the compound. This is one of the most frequent reasons a purchase goes wrong: one of the two requirements is discovered too late.

Zone classification can change

If production volume rises or ventilation deteriorates, an area can be reclassified. Equipment not certified for the new zone must be withdrawn from service immediately. That is worth weighing when choosing between an uncertified and a certified model for an area close to the threshold.

If you are unsure about your zone classification, consult an explosion safety adviser before purchasing. We are glad to help translate the classification into a concrete choice of machine. contact us.

Not sure about your zone classification?

Contact us with your zone classification and we identify the right ATEX category and model. Also read our ATEX ABC guide.