Product category • Tiger-Vac

Clean Room

ULPA U15-filtered vacuums for ISO 4 and above. Autoclavable, ESD-safe and GMP-compatible machines in stainless steel for pharmaceutical manufacturing and high-grade cleanrooms.

Clean Room — 16 models

CWR-10 EX (CV)

Tiger-Vac

CWR-10 EX (CV)

ATEX II 3D certified containment vacuum with sealed single-use canister in AISI 430 stainless steel — 12, 20 or 40 L. 5-stage filtration with dual ULPA U15. EMI/RFI shielded and ESD safe. ISO 4 compatible. OEB 4–5. 75 dB(A).

CD-1500 CR (PFB) WHITE LINE

Tiger-Vac

CD-1500 CR (PFB) WHITE LINE

Stationary cleanroom vacuum for pharmaceutical and food industry. TEFC motor for continuous duty, 187 m³/h airflow, ISO Class 4 compatible. Optional HEPA H14 and ULPA U15 filtration. Available in single-phase (230 V) and three-phase (400 V).

CD-1501 CR (STD) WHITE LINE

Tiger-Vac

CD-1501 CR (STD) WHITE LINE

Stationary cleanroom vacuum with powerful 1.7 kW TEFC motor for continuous duty. 238 m³/h airflow, 28.4 L recovery tank, ISO Class 4 compatible. Optional HEPA H14 and ULPA U15. Single-phase and three-phase available.

CD-2600 CR (ARP) WHITE LINE

Tiger-Vac

CD-2600 CR (ARP) WHITE LINE

Powerful stationary cleanroom vacuum with Automatic Reverse Purge (ARP) for process extraction. Up to 3.7 kW TEFC motor, 340 m³/h, 36 L detachable tank. ISO Class 4. Three-phase only (400 V).

CD-2600 CR (MRP) WHITE LINE

Tiger-Vac

CD-2600 CR (MRP) WHITE LINE

Powerful stationary cleanroom vacuum with Manual Reverse Purge (MRP) for process extraction. Up to 3.7 kW TEFC motor, 340 m³/h, 36 L detachable tank. ISO Class 4. Three-phase only (400 V).

CR-1 ULPA

Tiger-Vac

CR-1 ULPA

Cleanroom dry vacuum with ULPA U15 filtration. ISO 4 compatible. For pharma and semiconductor industries. 60 dB(A). 9 kg.

CR-1000 (CV)

Tiger-Vac

CR-1000 (CV)

Cleanroom containment vacuum with integrated safe containment canister for safe collection and disposal of potent and carcinogenic compounds. ULPA U15 + HEPA H14. 5-stage filtration. ISO 4 compatible. OEB 4–5. Autoclavable. 60 dB(A). 11 kg.

CR-1200D

Tiger-Vac

CR-1200D

Pharma cleanroom dry vacuum in electropolished AISI 316 stainless steel. ULPA U15 + HEPA H14 dual filtration system. ISO 4 compatible. Autoclavable tank. ESD safe. 70 dB(A). 16 kg.

CR-1300D

Tiger-Vac

CR-1300D

High-performance cleanroom vacuum in electropolished AISI 316 stainless steel. Dual ULPA U15 exhaust filtration. ISO 4 compatible. Autoclavable tank. Bypass motor. 194 m³/h. 28 kg.

CR-1300WD

Tiger-Vac

CR-1300WD

High-performance cleanroom vacuum for wet and dry recovery in electropolished AISI 316 stainless steel. Dual ULPA U15 exhaust filtration. ISO 4 compatible. Autoclavable tank and floater. Bypass motor. 194 m³/h. 28 kg.

CWR MRAC (10/15 L)

Tiger-Vac

CWR MRAC (10/15 L)

Pharmaceutical wet and dry recovery vacuum for cleanrooms with activated carbon middle ring (MRAC) for adsorption of toxic fumes. Dual ULPA U15, EMI/RFI shielded, ESD safe. ISO Class 4. 189 m³/h. 75 dB(A). Tank 28.4 L (CWR-10) or 47.3 L (CWR-15).

CWR-10 (PHARMA)

Tiger-Vac

CWR-10 (PHARMA)

Pharma-grade wet and dry recovery vacuum in electropolished stainless steel with ULPA U15 filtration — purpose-built for the recovery of broken ampules and glass fragments in ISO Class 4 cleanrooms.

MV-1CR (CV)

Tiger-Vac

MV-1CR (CV)

Compact pharmaceutical containment vacuum for cleanrooms and pharmaceutical production. Available as backpack (BP), handheld (HH) and golfcart (GC). Sealed containment HEPA H14 + ULPA U15. EMI/RFI shielded. ESD safe. ISO Class 4. 187 m³/h. 70 dB(A).

PHARMA 20.18

Delfin

PHARMA 20.18

Compact pharmaceutical dust collector in AISI 304 stainless steel. Star filter with manual cleaning. Optional H14 absolute filter. Safe bag system. Clamp ø50. 270 m³/h. 22 L.

PHARMA 40.30/40.40

Delfin

PHARMA 40.30/40.40

Large-scale pharmaceutical-grade stainless steel vacuum for cleanroom processes. AISI304 collection tank, H14 HEPA filter, Star-type media with manual cleaning. Dual motor sizes: 3-4 kW, 318-420 m³/h. OEB Level 3. Bag-in/bag-out containment optional.

TV-25L (DT) MFS HEPA WT

Tiger-Vac

TV-25L (DT) MFS HEPA WT

Industrial vacuum with regenerative blower for continuous 24/7 operation. 1.3 kW TEFC motor, 187 m³/h, 25 L detachable tank. HEPA H14 included. Manual Filter Shaker (MFS). GMP compliant. 230 V single-phase.

From ISO 8 to ISO 4, and what changes along the way

The Clean Room category covers machines that are allowed to stand inside the classified area. That places demands on three things at once: what the machine exhausts, what it is made of, and how it can be cleaned.

ULPA is not simply a better HEPA

From ISO class 5 upwards a ULPA filtered vacuum is required. ULPA U15 to EN 1822-1:2019 differs from HEPA on one point that matters in practice: the standard mandates a scan test using the PAO or DOP method to verify the integrity of the individual filter. The oil thread test permitted for H13 and H14 is not acceptable for U15. That is the difference between a filter tested as a type and a filter tested as a unit.

The ISO class says nothing about hazard

This is the most common misunderstanding in the category. ISO 14644-1 classifies the room by the number of particles per cubic metre. It says nothing about how hazardous those particles are. A machine suitable for ISO 4 is therefore not automatically suitable for OEB 4, unless the compound requires it as well. If you are handling highly potent compounds, OEB Facilities is the category to look in.

Material and cleanability

The machines are stainless steel, autoclavable and ESD safe. EU GMP Annex 1 from 2022 tightened the requirements for cleaning and disinfection in sterile environments and introduced the Contamination Control Strategy. The choice of cleaning equipment feeds directly into that strategy. Equipment must be cleanable to a validated end point, not merely wiped down.

If the machine has to be qualified with IQ/OQ/PQ, we supply the documentation package. contact us.

Not sure which Clean Room model you need?

We help specify the right machine for your ISO class and requirements.