ATEX Combi vacuum cleaner

Depureco MINIAIR 2V Z2/22

Pneumatic ATEX combined vacuum with 2 venturi -- Zone 22 dust + Zone 2 gas, 45 L tank, 300 m3/h, no electric motor

  • Refinery boundary zone with light HC vapour and combustible process dust
  • Battery factory -- electrolyte cans + lithium-bearing electrode dust
  • Smaller process handling points where an electric motor is not allowed
  • Paint-shop prep where solvents may be present
  • Pharma pilot production with combustible excipients (ATEX inside + Zone 2 gas)
Depureco MINIAIR 2V Z2/22 -- Pneumatic ATEX combined vacuum with 2 venturi -- Zone 22 dust + Zone 2 gas, 45 L tank, 300 m3/h, no electric motor
Certified to
  • ATEX Directive 2014/34/EU -- II 3D Ex h IIIC T140°C Dc -- II 3G Ex h IIB T3 Gc
  • EN 17348:2022 (harmonized March 2023)
  • IEC 60335-2-69 (industrial vacuums)

Depureco MINIAIR 2V Z2/22

The MINIAIR 2V Z2/22 is Depureco's smallest ATEX combined vacuum without an electric motor -- 2 venturi units drive the entire suction on compressed air alone. That means no electrical ignition source in the worked area: the whole unit is ATEX-certified II 3D + II 3G and therefore allowed in rooms with Zone 22 dust and Zone 2 gas simultaneously, which is typical for refinery boundary zones, battery production and smaller process handling points. 45 L AISI 304 tank, 300 m3/h flow, 500 mbar vacuum and 73 dB(A) -- compact (550 x 620 x 1150 mm) and wheeled for a single operator. Air consumption is 2500 Nl/min at 6-8 bar -- in practice a dedicated compressor outlet, not just a factory-standard air socket. H14 absolute filter (22,000 cm2 fiberglass, EN 1822-5) is optional, not standard.

Applications

  • Refinery boundary zone with light HC vapour and combustible process dust
  • Battery factory -- electrolyte cans + lithium-bearing electrode dust
  • Smaller process handling points where an electric motor is not allowed
  • Paint-shop prep where solvents may be present
  • Pharma pilot production with combustible excipients (ATEX inside + Zone 2 gas)

Technical specifications

ATEX markingII 3D Ex h IIIC T140°C Dc -- II 3G Ex h IIB T3 Gc
Internal / external zone22 / 22
Motor type2 venturi units, pneumatic operation (compressed air 6 bar)
Duty cycleContinuous
Airflow300 m³/h
Vacuum500 mbar (5097 mmH₂O)
Container45 L
Sound pressure73 dB(A)
Filter classM class
Filter typeAntistatic polyester star filter, class M, 15,000 cm2, manual cleaning (H14 22,000 cm2 fibreglass as add-on)
Primary filterAntistatic polyester star filter, class M, 15,000 cm2
Cleaning systemManuel filterrens
Collection systemDetachable container
MaterialPainted steel construction, AISI 304 dust container
Air consumption2500 nl/min
Supply pressure6-8 bar
Air supply hoseØ 12 mm
Venturi units2 pcs
InletØ 70 mm
Dimensions (L × W × H)550 x 620 x 1150 mm
Weight42 kg

Questions and answers

Why no electric motor?

Because the MINIAIR is designed for rooms where gas may be present. An electric motor -- even ATEX-certified -- has hot surfaces and contact elements that are a potential ignition source. Venturi operation has no moving electrical parts: the compressed air itself creates the vacuum through the nozzles. That is the safest construction for Zone 2 gas.

How much compressed air does it use?

2500 Nl/min at 6-8 bar (catalogue spec A672). That is not trivial: a small factory compressor (e.g. 5.5-7.5 kW with FAD of 500-1000 Nl/min) cannot support it alone. Count on at least 15-22 kW installed compressor capacity for continuous operation, and a refrigerant-dried air supply (PDP +3°C or better) to avoid condensation in the venturi nozzles.

What is the difference between MINIAIR 2V and AC 65 Z2/22?

The MINIAIR 2V is smaller (45 L) and has 2 venturi -- it is ideal for single-operator points. The AC 65 Z2/22 has the same ATEX marking but a larger 65 L container, broader filter area (24,000 cm2) and heavier suction cycling. Choose MINIAIR if space is tight and collection volume is small; AC 65 if there are multiple operators or longer run-time per shift.

Can it run continuously?

Yes. Venturi drive has no thermal limit as long as the compressed-air supply sustains the flow. The MINIAIR 2V is designed for continuous operation and has no duty-cycle restriction. In practice it is the compressor capacity that decides whether it is sustainable over a full shift -- check the compressor FAD against the 500 Nl/min consumption.

Is H14 absolute filter an option?

Yes, H14 is optional on the MINIAIR 2V Z2/22 -- not standard. Catalogue spec: 22,000 cm2 fiberglass, EN 1822-5, 99.995 % MPPS. Depureco part number P14904 (298.00 € from the price list). It is recommended if the collected dust is a CMR category or pharmaceutical. For factory-standard HEPA, see the AC 65 Z20/21 and AC 100 Z20/21 where 28,000 cm2 H14 is included.