ACD vacuum cleaner

Delfin DG VL 75 PN ACD

Three-phase ACD industrial vacuum with in-suction pneumatic filter cleaning -- 750 m³/h, 4500 mmH₂O, 24/7

  • Continuous collection of sticky dust (toner, colour pigments, resins)
  • Bakeries and flour mills running 24/7 flour production
  • Powder coating with high suction frequency
  • Food and pharmaceutical contract production requiring minimal downtime
  • Central-vacuum-style installations with fixed pick-up points and long hose runs
Delfin DG VL 75 PN ACD -- Three-phase ACD industrial vacuum with in-suction pneumatic filter cleaning -- 750 m³/h, 4500 mmH₂O, 24/7
Certified to
  • IEC 60335-2-69 Annex AA (ACD)
  • Low Voltage Directive 2014/35/EU
  • EMC Directive 2014/30/EU

Delfin DG VL 75 PN ACD

The Delfin DG VL 75 PN ACD is the cartridge-filter variant of the DG VL series, designed for sticky or demanding dust and for 24/7 duty without interruption. Where the standard version purges the star filter between cycles, the PN version runs pneumatic filter cleaning during suction: compressed-air pulses hit the four cartridges in turn while vacuum continues, shaking the dust cake off the filter surface in real time (750 m³/h, 4500 mmH₂O). The motor is maintenance-free, and no scheduled downtime for filter shaking is required. Certification and internal Zone 20 construction follow IEC 60335-2-69 Annex AA as on the standard series.

Applications

  • Continuous collection of sticky dust (toner, colour pigments, resins)
  • Bakeries and flour mills running 24/7 flour production
  • Powder coating with high suction frequency
  • Food and pharmaceutical contract production requiring minimal downtime
  • Central-vacuum-style installations with fixed pick-up points and long hose runs

Technical specifications

ATEX markingCE ACD -- complies with IEC 60335-2-69 Annex AA (not ATEX-marked) -- class H, HEPA H14 (EN 1822-5, 99.995 % MPPS)
Internal / external zone20 / non-ATEX
Motor typeThree-phase side-channel blower, maintenance-free
Duty cycleContinuous
Airflow750 m³/h
Vacuum441 mbar (4500 mmH₂O)
Container160 L
Sound pressure72 dB(A)
Filter classH class
Filter typeClass H HEPA H14, 52,000 cm² filter area (99.995 % MPPS, EN 1822-5)
Primary filter4 x polyester class M cartridge filters (106,000 cm² active filter area in total, polyester ANT M), vertically mounted
Cleaning systemPN -- pneumatic filter cleaning during operation (compressed-air pulses hit the 4 cartridges in sequence, integrated compressor, 24/7 operation without planned filter stops)
Collection systemDetachable container
MaterialFully painted steel cabinet with reinforced frame for forklift lifting
IP classIP55
Power7.5 kW
Current13.3 A
Voltage400 V / 50 Hz / 3~
InletØ 120 mm
Dimensions (L × W × H)1700 x 740 x 2130 mm
Weight360 kg

Questions and answers

What is the difference between PN and the standard version?

The PN version has four cylindrical cartridge filters (106,000 cm² total) and runs pneumatic filter cleaning DURING suction, where the standard version uses a star filter (70,000 cm²) and SELF CLEAN between cycles. Choose PN for 24/7 duty and for sticky dust types.

Why is the PN version 13 cm taller than the standard?

The cartridge filters require more vertical space (213 cm vs 200 cm). Diameter and footprint are unchanged.

Can I use PN ACD in an ATEX Zone 22?

No. Like all ACD models, the DG VL PN ACD is certified to IEC 60335-2-69 Annex AA and is intended only for non-ATEX-classified areas.

How often do the cartridge filters need replacing?

With pneumatic cleaning during suction, filter life is significantly extended -- typically 12-24 months of operation depending on dust type. Filter load is 68-127 m³/m²/h depending on model, roughly 35 % lower than the standard version.

Is the motor truly maintenance-free?

The sealed, oil-free side-channel blower has no carbon brushes or seals to replace. No scheduled motor service is needed during normal operating life. The compressor driving the cleaning system has its own service intervals specified by the manufacturer.

Is the H14 HEPA filter included?

Yes, as on the standard version. H-class HEPA H14 with 99.995 % MPPS efficiency per EN 1822-5.

Need advice on this model?