ACD vacuum cleaner

Delfin DG 300 HD PN ACD

Three-phase side-channel ACD vacuum with PN cartridge cleaning -- 2050 m³/h, 4000/3100 mmH₂O, 220 L, on-board compressor

  • Continuous large-scale production cleaning with 24/7 duty
  • Dust collection at centralised installations with large piping
  • Woodworking with constant MDF and fine particle production
  • Metalworking with high duty cycle and combustible grinding dust
  • Stationary installations where filter pauses are not acceptable
Delfin DG 300 HD PN ACD -- Three-phase side-channel ACD vacuum with PN cartridge cleaning -- 2050 m³/h, 4000/3100 mmH₂O, 220 L, on-board compressor
Certified to
  • IEC 60335-2-69 Annex AA (ACD)
  • Low Voltage Directive 2014/35/EU
  • EMC Directive 2014/30/EU

Delfin DG 300 HD PN ACD

The Delfin DG 300 HD PN ACD is the high-flow PN version of the 300 range -- 25 kW three-phase side-channel blower, 2050 m³/h airflow, 4000 mmH₂O max vacuum (3100 mmH₂O continuous) and four polyester class M cartridge filters totalling 260.000 cm². Pneumatic cleaning (PN) pulses compressed air through the cartridges while suction continues -- no pauses, no manual shaking, constant high suction performance. Compressor is included on-board. The footprint is larger than the AUT version (920 x 2200 vs 950 x 1800 mm base), but the lower air load (79 m³/m²/h) yields significantly longer filter life.

Applications

  • Continuous large-scale production cleaning with 24/7 duty
  • Dust collection at centralised installations with large piping
  • Woodworking with constant MDF and fine particle production
  • Metalworking with high duty cycle and combustible grinding dust
  • Stationary installations where filter pauses are not acceptable

Technical specifications

ATEX markingCE ACD -- complies with IEC 60335-2-69 Annex AA (not ATEX-marked) -- class H, HEPA H14 (EN 1822-5, 99.995 % MPPS)
Internal / external zone20 / non-ATEX
Motor typeThree-phase side-channel blower -- 25 kW
Duty cycleContinuous
Airflow2050 m³/h
Vacuum392 mbar (4000 mmH₂O)
Container220 L
Sound pressure78 dB(A)
Filter classH class
Filter typeClass H HEPA H14, 103,500 cm² filter area (99.995 % MPPS, EN 1822-5)
Primary filter4 x polyester class M cartridge filters (260,000 cm² active filter area, polyester ANT M)
Cleaning systemPN -- pneumatic filter cleaning during operation (on-board compressor, compressed-air pulse cleaning of the cartridges without stopping suction)
Collection systemDetachable container
MaterialPainted steel cabinet as standard, stainless steel AISI 304 as option
IP classIP65
Power25.0 kW
Current46.0 A
Voltage400 V / 50 Hz / 3~
InletØ 120 mm
Dimensions (L × W × H)920 x 2200 x 2200 mm
Weight825 kg

Questions and answers

Why PN over AUT?

The PN system cleans cartridges during suction via compressed air pulses, keeping vacuum performance constantly high without pauses. AUT only shakes between cycles and suits periodic use. Choose PN for 24/7 production.

What is the filter life difference between HD and HD PN?

HD (AUT) has a filter load around 200 m³/m²/h. HD PN has 79 m³/m²/h thanks to the much larger 260.000 cm² cartridge area -- roughly three times longer filter life under similar conditions.

Is the compressor included?

Yes -- on-board compressor is built in. No external compressed air connection required.

How often do cartridge filters need replacing?

With pneumatic cleaning during suction, filter life is significantly extended -- typically 12-24 months depending on dust type, filter load and cleaning frequency.

Can I use the DG 300 HD PN ACD in ATEX Zone 22?

No. Like all ACD models, DG 300 HD PN is certified to IEC 60335-2-69 Annex AA and intended only for non-ATEX-classified areas.

How much noise does the compressor add?

The overall sound level is 78 dB(A) measured per EN ISO 3744. The compressor runs only in short pulses and does not raise the overall level above the stated value.

Need advice on this model?